The influence of the microscope lamp filament colour temperature on the process of digital images of histological slides acquisition standardization.

The influence of the microscope lamp filament colour temperature on the process of digital images of histological slides acquisition standardization.

BACKGROUND
The purpose of this study was to compare the digital image of the biopsy tissue taken with an optical microscope using bright field techniques under various lighting conditions. Various colors in immunohistochemistry stained with 3,3′-diaminobenzidine and Haematoxylin very large and tissue samples derived from various sources. One of them is the inadequate arrangements camera’s white balance color temperature of the light microscope.

Although these types of errors can be easily handled during the image acquisition phase, can be eliminated by using a color adjustment algorithms. Examination of the color variation of the temperature dependence of light microscope and camera settings is done as a preliminary study for automatic color standardization process.


METHOD
Six field of view with an empty space between these tissue samples selected for analysis. Each field of view has acquired 225 times with mild temperatures variety of microscopes and camera white balance settings. Fourteen of randomly selected images has been improved and compared with reference images, by the following methods: Mean Square Error, Structural similarity and a visual assessment viewer.


RESULTS
For the two types of background and two types of objects, descriptors statistical picture: the range, median, mean and standard deviation of the chromaticity on the A and B channels of the CIELAB color space, and lighting L, and the variability of local color to a specific area objects have counted. The result has been the average over the six images obtained in the same light conditions and camera settings for each sample.


CONCLUSION
Analysis of lead results following conclusions: (1) the images collected with the white balance adjusted for cluster color temperature of light in certain regions of space chromatic, (2) the process of correction of white balance to the images collected by the camera white balance settings are not suitable for the temperature light the explanatory moving picture to the right color space but at the same time value the lighting changes. So the unification process in terms of color fidelity image can be completed in a separate introductory stage before automatic image analysis.

 The influence of the microscope lamp filament colour temperature on the process of digital images of histological slides acquisition standardization.
The influence of the microscope lamp filament colour temperature on the process of digital images of histological slides acquisition standardization.

centrosome research historical roots: the invention of the microscope slide Boveri in Würzburg.

Boveri visionary monograph ‘Ueber die Natur der Centrosomen’ (On the nature of centrosomes) in 1900 founded largely on microscopic observations of sea urchin egg divides and Ascaris roundworm parasites.

As Boveri wrote in the introductory paragraph, less importance on morphological aspects of centrosomes, but aimed at an understanding of their physiological roles during cell division. The remarkable transition from observations of small dot-like structure remains and pieces of material for a unified theory of centrosome function (which is basically still true today) can not be fully appreciated without checking this starting material Boveri, histological specimens.

Superfrost® Plus microscope slides

PO103 box (72 slides)
EUR 94.55
Description: Best quality products

Gold Seal Rite-On® frosted slides

PO104 box (72 slides)
EUR 83.71
Description: Best quality products

Gelatin-coated microscope slides (75 x 25 mm)

PO101 100 slides
EUR 186.41
Description: Best quality products

Gelatin-coated microscope slides (75 x 50 mm)

PO105 100 slides
EUR 334.25
Description: Best quality products

100-place microscope slide box (for 75 x 25 mm slides)

PO201 each
EUR 67.03
Description: Best quality products

25-place microscope slide box (for 75 x 25 mm slides)

PO202 each
EUR 59.1
Description: Best quality products

100-place microscope slide box (for 75 x 50 mm slides)

PO203 each
EUR 114.36
Description: Best quality products

Microscope slide dispenser for box of 72 standard 25 x 75mm slides

M7100-SD 1/pack
EUR 69.91
Description: Microscope slide dispenser

Bovine enterovirus (BEV) PCR kit

PCR-V728-48D 50T
EUR 425.8
  • Contact us in order to know the reactivity of the kit.
Description: An conventional PCR kit for detection of Bovine enterovirus (BEV)

Bovine enterovirus (BEV) PCR kit

PCR-V728-96D 100T
EUR 521.5
  • Contact us in order to know the reactivity of the kit.
Description: An conventional PCR kit for detection of Bovine enterovirus (BEV)

Bovine enterovirus (BEV) RT PCR kit

RTq-V728-100D 100T
EUR 628.5
  • Contact us in order to know the reactivity of the kit.
Description: A Real-Time PCR kit for detection of Bovine enterovirus (BEV) .

Bovine enterovirus (BEV) RT PCR kit

RTq-V728-150D 150T
EUR 701
  • Contact us in order to know the reactivity of the kit.
Description: A Real-Time PCR kit for detection of Bovine enterovirus (BEV) .

Bovine enterovirus (BEV) RT PCR kit

RTq-V728-50R 50T
EUR 631.4
  • Contact us in order to know the reactivity of the kit.
Description: A Real-Time PCR kit for detection of Bovine enterovirus (BEV) .

Positive control tissue section for each antibody; Based on availability INQUIRE

Control-Slides Set of 5
EUR 176

Bovine enterovirus (BEV) One-Step PCR kit

Oneq-V728-100D 100T
EUR 747.4
  • Contact us in order to know the reactivity of the kit.
Description: Real Time PCR Kit is a screening assay for a rapid and accurate detection of Bovine enterovirus (BEV).

Bovine enterovirus (BEV) One-Step PCR kit

Oneq-V728-150D 150T
EUR 838.75
  • Contact us in order to know the reactivity of the kit.
Description: Real Time PCR Kit is a screening assay for a rapid and accurate detection of Bovine enterovirus (BEV).

Bovine enterovirus (BEV) One-Step PCR kit

Oneq-V728-50D 50T
EUR 628.5
  • Contact us in order to know the reactivity of the kit.
Description: Real Time PCR Kit is a screening assay for a rapid and accurate detection of Bovine enterovirus (BEV).

ReadiUse™ microscope mounting solution

20009 50 mL
EUR 115
  • R-phrase: R20, R21, R22
  • H-Phrase: H303, H313, H333
  • Symbol for dangerous compounds: Xn
  • UNSPEC Code: 12352200

Amyloid (Control Slides)

TCS0003-100 100 Slides
EUR 706

Amyloid (Control Slides)

TCS0003-25 25 Slides
EUR 232

Amyloid (Control Slides)

TCS0003-5 5 Slides
EUR 98

Argentaffin (Control Slides)

TCS0004-100 100 Slides
EUR 706

Argentaffin (Control Slides)

TCS0004-25 25 Slides
EUR 232

Argentaffin (Control Slides)

TCS0004-5 5 Slides
EUR 98

Fungus (Control Slides)

TCS0005-100 100 Slides
EUR 706

Fungus (Control Slides)

TCS0005-25 25 Slides
EUR 232

Fungus (Control Slides)

TCS0005-5 5 Slides
EUR 98

Bielschowsky's (Control Slides)

TCS0006-100 100 Slides
EUR 706

Bielschowsky's (Control Slides)

TCS0006-25 25 Slides
EUR 232

Bielschowsky's (Control Slides)

TCS0006-5 5 Slides
EUR 98

Calcium (Control Slides)

TCS0007-100 100 Slides
EUR 706

Calcium (Control Slides)

TCS0007-25 25 Slides
EUR 232

Calcium (Control Slides)

TCS0007-5 5 Slides
EUR 98

Elastic (Control Slides)

TCS0008-100 100 Slides
EUR 706

Elastic (Control Slides)

TCS0008-25 25 Slides
EUR 232

Elastic (Control Slides)

TCS0008-5 5 Slides
EUR 98

Melanin (Control Slides)

TCS0015-100 100 Slides
EUR 706

Melanin (Control Slides)

TCS0015-25 25 Slides
EUR 232

Melanin (Control Slides)

TCS0015-5 5 Slides
EUR 98

Mucin (Control Slides)

TCS0016-100 100 Slides
EUR 706

Mucin (Control Slides)

TCS0016-25 25 Slides
EUR 232

Mucin (Control Slides)

TCS0016-5 5 Slides
EUR 98

Reticulum (Control Slides)

TCS0019-100 100 Slides
EUR 706

Reticulum (Control Slides)

TCS0019-25 25 Slides
EUR 232

Reticulum (Control Slides)

TCS0019-5 5 Slides
EUR 98

Microscope Slide Boxes,100-Place, Blue

LC7002-001 Ea
EUR 70

Microscope Slide Boxes,100-Place, Blue

LC7002-010 10/PK
EUR 151

Microscope Slide Boxes,100-Place, Blue

LC7002-100 100/CS
EUR 806

Microscope Slide Boxes,100-Place, Green

LC7003-001 Ea
EUR 70

Microscope Slide Boxes,100-Place, Green

LC7003-010 10/PK
EUR 151

Microscope Slide Boxes,100-Place, Green

LC7003-100 100/CS
EUR 806

Microscope Slide Boxes,100-Place, Red

LC7004-001 Ea
EUR 70

Microscope Slide Boxes,100-Place, Red

LC7004-010 10/PK
EUR 151

Microscope Slide Boxes,100-Place, Red

LC7004-100 100/CS
EUR 806

Microscope Slide Boxes,100-Place, Yellow

LC7005-001 Ea
EUR 70

Microscope Slide Boxes,100-Place, Yellow

LC7005-010 10/PK
EUR 151

Microscope Slide Boxes,100-Place, Yellow

LC7005-100 100/CS
EUR 806

Microscope Slide Boxes,100-Place, White

LC7006-001 Ea
EUR 70

Microscope Slide Boxes,100-Place, White

LC7006-010 10/PK
EUR 151

Microscope Slide Boxes,100-Place, White

LC7006-100 100/CS
EUR 806

Microscope Slide Boxes,25-Place, Blue

LC7007-001 EA
EUR 66

Microscope Slide Boxes,25-Place, Blue

LC7007-010 10/PK
EUR 124

Microscope Slide Boxes,25-Place, Blue

LC7007-100 100/CS
EUR 570

Microscope Slide Boxes,25-Place, Green

LC7008-001 EA
EUR 66

Microscope Slide Boxes,25-Place, Green

LC7008-010 10/PK
EUR 124

Microscope Slide Boxes,25-Place, Green

LC7008-100 100/CS
EUR 570

Microscope Slide Boxes,25-Place, Red

LC7009-001 EA
EUR 66

Microscope Slide Boxes,25-Place, Red

LC7009-010 10/PK
EUR 124

Microscope Slide Boxes,25-Place, Red

LC7009-100 100/CS
EUR 570

Microscope Slide Boxes,25-Place, Yellow

LC7010-001 EA
EUR 66

Microscope Slide Boxes,25-Place, Yellow

LC7010-010 10/PK
EUR 124

Microscope Slide Boxes,25-Place, Yellow

LC7010-100 100/CS
EUR 570

Microscope Slide Boxes,25-Place, White

LC7011-001 EA
EUR 66

Microscope Slide Boxes,25-Place, White

LC7011-010 10/PK
EUR 124

Microscope Slide Boxes,25-Place, White

LC7011-100 100/CS
EUR 570

CometAssay High Throughput Slides

4252-02K-01 100 tests
EUR 1619.4

CometAssay Alkaline Control Slides

4256-010-CC 10 Tests
EUR 324.4

CometAssay Neutral Control Slides

4257-010-NC 10 Tests
EUR 324.4

Alcian Blue (Control Slides)

TCS0002-100 100 Slides
EUR 706

Alcian Blue (Control Slides)

TCS0002-25 25 Slides
EUR 232

Alcian Blue (Control Slides)

TCS0002-5 5 Slides
EUR 98

Helicobacter Pylori (Control Slides)

TCS0011-100 100 Slides
EUR 706

Helicobacter Pylori (Control Slides)

TCS0011-25 25 Slides
EUR 232

Helicobacter Pylori (Control Slides)

TCS0011-5 5 Slides
EUR 98

Iron - Liver (Control Slides)

TCS0013-100 100 Slides
EUR 706

Iron - Liver (Control Slides)

TCS0013-25 25 Slides
EUR 232

Iron - Liver (Control Slides)

TCS0013-5 5 Slides
EUR 98

Mast Cell (Control Slides)

TCS0014-100 100 Slides
EUR 706

Mast Cell (Control Slides)

TCS0014-25 25 Slides
EUR 232

Mast Cell (Control Slides)

TCS0014-5 5 Slides
EUR 98

PAS/Glycogen (Control Slides)

TCS0017-100 100 Slides
EUR 706

PAS/Glycogen (Control Slides)

TCS0017-25 25 Slides
EUR 232

PAS/Glycogen (Control Slides)

TCS0017-5 5 Slides
EUR 98

Trichrome - Colon (Control Slides)

TCS0021-100 100 Slides
EUR 706

Trichrome - Colon (Control Slides)

TCS0021-25 25 Slides
EUR 232

Trichrome - Colon (Control Slides)

TCS0021-5 5 Slides
EUR 98

Trichrome - Liver (Control Slides)

TCS0022-100 100 Slides
EUR 706

It is generally assumed that the microscope slides are lost during the bombing of the Zoological Institute in Würzburg at the end of World War II. Here, I describe the discovery of a number of original microscope slides Boveri with early serial section and Ascaris sea urchin embryo, stained with hematoxylin iron HEIDENHAIN this method. Some slides bear handwritten notes and sketches by Boveri. Evidence is presented that the new slide is found is part of the original materials used by Boveri’s seminal monograph centrosome.

Leave A Comment